- Power Supply & LED driver
- Adaptor AC-DC
- Voltage Stabilizer,Regulator,UPS
- LED Light
- Power Inverter DC-AC
- Cable Accessory
120W Single Output Switching Power Supply
Technical Data
Index Type |
S-120-5 |
S-120-7.5 |
S-120-12 |
S-120-15 |
S-120-24 |
S-120-48 |
DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
48V |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
Rated Current |
24A |
16A |
10A |
8A |
5A |
2.5A |
Current Range |
0-24A |
0-16A |
0-10A |
0-8A |
0-5A |
0-2.5A |
Ripple&Noise(Max.) |
100mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
Load Regulation |
±1% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
Rated Power |
120W |
120W |
120W |
120W |
120W |
120W |
Efficiency |
76% |
78% |
80% |
81% |
83% |
84% |
Voltage Adjust Range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
Voltage Range |
85~132VAC/176-264VAC auto switch 47~63Hz;248~370VDC |
|||||
AC Current |
2.4A/115V1.2A/230V |
|||||
Inrush Current(Max.) |
cold start current 30A/115V60A/230V |
|||||
Leakage Current |
<1mA/240VAC |
|||||
Overload Protection |
125%-165% TYPE:OUTPUT CUTOUT AUTO RECOVERY |
|||||
Over-voltage Protection |
115%-135% |
|||||
Over-temperature Protection |
...................... |
|||||
Temp.Coefficient |
±0.03%/℃(0~50℃) |
|||||
Setup.Rise,Hold Time |
1s,30ms,15ms |
|||||
Vibration |
10~500Hz,2G10min,/11cycle,60min,each axes |
|||||
Withstand Voltage |
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC |
|||||
Isolated Resistor |
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ |
|||||
Working Temp.Humidity |
-10℃~+60℃(REFER TO CHARACTER CURVE),20%~90RH |
|||||
Storage Temp.Humidity |
-20℃~+85℃,10%~95%RH |
|||||
Dimension |
199×98×38mm |
|||||
Weight |
0.70kg |
|||||
Safety Standards |
UL1012 TUV60950(IEC950,UL1950) |
|||||
EMC |
CISPR22(55022),IEC801-2,3,4,IEC555-2 |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance,line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation:min&max voltage of the rated load.
5.load regulation:load from 0 to 100%.