30W Triple Output Switching Power Supply
Technical Data
Index Type |
T-30A |
T-30B |
||||
DC Voltage |
5V |
12V |
-5V |
5V |
12V |
-12V |
Voltage Adjust Range |
+10%--5% |
|
|
+10%--5% |
|
|
Voltage Tolerance |
±2% |
+2%-6% |
+2%-10% |
±2% |
+2%-6% |
±6% |
Rated Current |
3A |
1A |
0.5A |
3A |
1A |
0.5A |
Current Range |
0.5-3A |
0.1-1A |
0.1-0.5A |
0.5-3A |
0.1-1A |
0.1-0.5A |
Rated Power |
29.5W |
33W |
||||
Efficiency |
70% |
72% |
||||
Ripple&Noise(Max.) |
50mvp-p |
100mvp-p |
50mvp-p |
50mvp-p |
100mvp-p |
100mvp-p |
Line Regulation |
±0.5% |
±1% |
±1% |
±0.5% |
±1% |
±1% |
Load Regulation |
±0.5% |
±5% |
±5% |
±0.5% |
±5% |
±5% |
Voltage Range |
85-132VAC/170-264VAC 47-63Hz 240-370VDC |
|||||
AC Current |
0.8A/115V0.45A/230V |
|||||
Inrush Current(Max.) |
cold start current18A/115V36A/230V |
|||||
Leakage Current |
<1mA/240V |
|||||
Overload Protection |
105-150% type :current limitation auto recovery |
|||||
Over-voltage Protection |
------ |
|||||
Over-temperature Protection |
------ |
|||||
Temp.Coefficient |
±0.03%/℃(0-50℃) |
|||||
Setup.Rise,Hold Time |
200ms 100ms 300ms /230V |
|||||
Withstand Voltage |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
|||||
Isolated Resistor |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ |
|||||
Storage Temp.Humidity |
0-50℃@100%,-10℃@80%,60℃@60%,20%-90%RH |
|||||
Weight |
0.45 Kg |
|||||
Safety Standards |
UL1012 |
|||||
EMC |
FCC part15.conduction |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance,line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.Line regulation:min&max voltage of the rated load.
5.Load regulation:load from 0 to 100%