- Power Supply & LED driver
- Adaptor AC-DC
- Voltage Stabilizer,Regulator,UPS
- LED Light
- Power Inverter DC-AC
- Cable Accessory
50W Single Output DC-DC Power Supply SDD-50
Features:
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83 KHz
Low cost
High reliability
2 years warranty
SPECIFICATION |
|||||||||
OUTPUT |
|
||||||||
Model |
SDD-50A-5 |
SDD-50B-5 |
SDD-50C-5 |
SDD-50A-12 |
SDD-50B-12 |
SDD-50C-12 |
SDD-50A-24 |
SDD-50B-24 |
SDD-50C-24 |
DC Voltage |
5V |
12V |
24V |
||||||
Rated Current |
10A |
4.2A |
2.1A |
||||||
Current Range |
0~10A |
0~4.2A |
0~2.1A |
||||||
Rated Power |
50W |
50.4W |
50.4W |
||||||
Ripple & Noise |
100mVp-p |
120mVp-p |
150mVp-p |
||||||
Voltage Adj. Range |
4.5~5.5VDC |
11~16VDC |
23~30VDC |
||||||
Voltage Tolerance |
±2.0% |
±1.0% |
±1.0% |
||||||
Line Regulation |
±0.5% |
±0.3% |
±0.2% |
||||||
Load Regulation |
±0.5% |
±0.3% |
±0.2% |
||||||
Setup, Rise, Hold Up Time |
2.5s,50ms,------at full load |
||||||||
|
|
||||||||
INPUT |
|
||||||||
Voltage Range |
A:9.2~18VDC B:19~36VDC C:36~72VDC |
||||||||
Efficiency |
70% |
73% |
76% |
72% |
75% |
78% |
74% |
80% |
83% |
DC Current |
A:7A/12V |
B:3A/24V |
C:1.5A/48V |
||||||
|
|
||||||||
PROTECTION |
|
||||||||
Over Load |
105~150% rated output power |
||||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed |
|||||||||
Over Voltage |
5.75~6.75V/10%load |
16.8~20V/10%load |
31.5~37.5V/10%load |
||||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed |
|||||||||
|
|
||||||||
ENVIRONMENT |
|
||||||||
Working Temp. |
-10~+60℃ (Refer to "Derating Curve") |
||||||||
Working Humidity |
20~90% RH non-condensing |
||||||||
Storagetemp.,Humidity |
-20~+85℃ ,10~95%RH |
||||||||
Temp.Coefficient |
±0.03%/℃ (0~50℃) |
||||||||
Vibration |
10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes |
||||||||
|
|
||||||||
SAFETY |
|
||||||||
Safety Standards |
Design refer to LVD |
||||||||
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
|
||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC /25℃ /70%RH
|
||||||||
EMC Emission |
Compliance to EN55022(CISPR22)Class B |
||||||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,6,8, EN55024, heavy industry level, criteria A |
||||||||
|
|
||||||||
OTHERS |
|
||||||||
Dimension |
159*98*38mm (L*W*H) |
||||||||
Weight |
0.46kg |
||||||||
|
|
||||||||
NOTE |
|
||||||||
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives |